Technical library
Pipeline inspection methods and data
How in-line inspection works, from measurement physics to signal processing. Includes reviews of published research.
Our engineers explain what each system measures, how its components work and what affects the results. Each article includes practical conclusions and references for further reading.
Terminology dictionary →International research and practice →
Results: 58
International research
Assessing pipeline dents: why the measurement method matters
Compare caliper and laser scan data, account for dent shape and proceed from screening to calculation.
Read article →International research
AI-assisted crack detection: what it takes beyond a neural network
TRAPIL and MP Data Technologies examine automatic anomaly detection, false alarms and the role of expert review.
Read article →International research
Tethered pipeline robots: inspecting a section from a single access point
NDT Global and TSC Subsea explore propulsion, retrieval, measurement coverage and the distinction between full and local inspection.
Read article →International research
Accuracy of MFL after I.I.: Why keep checking the result
From magnetic signal to size estimation: models, field reference points, individual errors and change control.
Read article →International research
Ormen Lange: How pipeline preparation determines success of diagnostics
Deep-water gas pipeline, altitude variation and sediment: Engineering lessons of ROSEN, Shell and Pipeline Innovations.
Read article →International research
Axis deformation of the pipe: One inertial navigation missing
The Baker Huges experience and engineering review: bend, longitudinal deformation, load and carrying capacity — The different parts of the problem.
Read article →International research
Underwater crossing without launch cameras: opportunities and limits of robotic control
Intero project on existing gas pipelines: access management, navigation, coating and quality of final data.
Read article →International research
Acoustic Resonance in the Gas pipeline: Where the Method works and where the Task changes
The 10-year NDT Global experience helps to distinguish between wall thickness measurement and internal surface observation.
Read article →International research
Small diameter — big engineering challenge for in-line detection tool
Combination of MFL, profile and IMU in close space: KMAX lessons and criteria for meaningful tests.
Read article →International research
Deposition or corrosion: Why combine geometry and magnetic measurements
Case 3P Services on the thickest sea pipeline and self-discussing the mixed signals.
Read article →International research
Longitudinal corrosion: Why maximum depth alone is not sufficient
Ultrasound topography, comparison with MFL and preparation of data for long corrosion damage.
Read article →International research
Deep-water diagnostics: why a set of solutions is needed, not one universal instrument
ROSEN approach to combining methods and modes of delivery on lines with thick wall, flexible rangers and limited access.
Read article →International research
All measurements per passage: What is behind the combined ultrasonic control
The TRACIL experience with phased bars and the trade-offs between coating, speed, data volume and verification.
Read article →International research
Error for each defect: How accuracy MFL affects the engineering decision
A detailed review of Baker Hughes: individual size intervals, independent verification and use of uncertainty in status assessment.
Read article →International research
Unknown bottom connection: how geometry fittings alter the design of the inspection tool
3P Services project shows the relationship between archival records, passable layout, seals and measuring passage.
Read article →International research
Robot per kilometre: why range is determined by infrastructure and energy
Intero experience with in-line charging: autonomy, access points, data coverage and full survey cost.
Read article →International research
Flexible Razer: What can be learned from the geometry of the inner shell
Equinor case and NDT Global: two-directional ultrasonic control, a step of the framework and the position of the end compounds.
Read article →International research
Flexible sea pipes: why one measuring tunnel is not sufficient
Multilayer design, availability of selected elements and the relationship of in-line measurements to the control of the integrity of a flexible pipeline.
Read article →International research
Longitudinal deformation of the pipeline: how to compare load and ability to withstand it
Why the bend from IMU does not describe all longitudinal deformation and why a limit value cannot be set the same for the whole track.
Read article →International research
Hydrogen or CO₂ pipeline conversion: why the previous survey is not sufficient
How a change in transportable environments is rebuilding the list of threats, data requirements and the validation program for the existing line.
Read article →International research
Acoustic Resonance and Variable Diameter: How Instrumental Performance is Proved
Distribution of ART as a measurement principle and test program for complex sea lanes with diameter crossings.
Read article →International research
Hydrogen pipeline instrument: material compatibility, magnetic system and motion
Why the adaptation of MFL to hydrogen environment affects the whole design and requires testing of the operating dynamics.
Read article →International research
Extension of the maritime line: Why combine geometry, MFL and ultrasound
Experience of Guillemot West surveys and the role of independent verification in moving from diagnostic recording to justification for further use.
Read article →International research
Hydraulic before diagnosis: How to calculate the movement of the inspection tool in a complex line
The supply of liquid, altitude variation, cleaning and restriction of the receiver in a single model for the preparation of an in-lineral survey.
Read article →International research
Arctic Marine Line Inspection: Why a stand is more important than a geographical record
The Goliat experience shows the role of real sectional, rock test and backup configuration.
Read article →International research
A stopped inspection tool: What TDW engineering teaches
As a cause analysis, the re-establishment of the knot geometry and model testing help to determine a reasonable solution in non-crash traffic.
Read article →International research
MFL accuracy: why the number of sensors does not determine the quality of the report
Detection, classification, size evaluation and data verification as separate magnetic diagnostics.
Read article →International research
Complex Fracture and Ultrasound: Why one strong echo signal can be misleading
Orientation, inclination, reflectivity and independent dimensional verification of the development of internal ultrasonic monitoring.
Read article →International research
Ryser without flow: How the architecture of the in-liner survey changes
Delivery, control and surface completeness of the measuring node in the absence of normal traffic flow.
Read article →International research
Paraphine, low-end and thick wall: review of the Apache project
Why the choice between MFL and UT depends on the combination of conditions, and the cleaning and design of the magnetic system must be considered together.
Read article →International research
Ultrasound geometry: What is needed to have a reliable dent profile
How the measurement of distance to the wall becomes a geometric model and why the sampling step, error and verification conditions cannot be mixed.
Read article →International research
Ultrasound crack control: how electronics determine speed and coating
Time window, parallel channels and environmental properties in the multi-channel interpiper architecture.
Read article →International research
Shell FLAGS: How to check the instrument for a wide range of modes
Low flow, lateral flow, fittings and wear in the overall MFL maritime qualification programme.
Read article →International research
If the internal tube inspection is not yet possible: how to select the locations of external inspection
Sample ultrasound surveys, terrain, water accumulation and limits of findings on several available sealine sections.
Read article →International research
Connecting through the pipe wall: How to understand the state of the instrument that cannot be seen
The passing mark, the identification of the device and the two-way communication are different tasks. We look at the internal tube control architecture using the TDW.
Read article →International research
MFL grid: Why a detailed picture is not yet equal to the laser dimension
Which reduces the distance between magnetic sensors and what it requires for mechanics, normalization and corrosion analysis.
Read article →International research
Ultrasound in CRA pipes: What wall does the instrument really see?
The entire corrosion resistant material, the crying pipe and the mechanically installed liner require different ultrasonic control models.
Read article →International research
Increasing corrosion between surveys: Why not just subtract two depths
The convergence of signals, the stability of coordinates and the uncertainty of measurement determine the reliability of the corrosion rate assessment.
Read article →International research
Rapid ultrasonic monitoring: inspection tool speed and data quality
The EVO generation is an example of why increased speed requires harmonization of acoustics, interview frequencies, memory and surface control algorithms.
Read article →International research
Complex pipeline: How to divide inspection into verifiable restrictions
ROSEN approach to difficult lines helps separate access, movement and measurement — Three conditions for a successful survey.
Read article →International research
Magnetic, virtic or ultrasonic control CRA: How to separate tasks
A multilayer corrosion resistant tube requires a monitoring map: what is the method for liner, main metal and geometry?
Read article →International research
How to check MFL with an independent ultrasound and not compare various defects
The marine example of PII shows the role of accurate data matching and representative sample when checking in-line accuracy.
Read article →International research
Long longitudinal corrosion: Why the calculation needs a wall profile
One maximum depth does not describe the long corrosion tunnel. We're going to go from ultrasonic map to state assessment.
Read article →International research
Primary inspection of deep sea line: data required in years
The sea pipeline project shows why the baseline survey needs to be planned together with the introduction of the facility and a future comparison of results.
Read article →International research
Small ulcer, big problem: as the detection of pinhole corrosion confirms
Why the diameter of the local damage, the position of the sensors and the shape of the wall are as important as its depth.
Read article →International research
A composite two-directional inspection tool: What changes when returned the same way
The reverse movement involves cuffs, magnetic system, cleaning, coordinates and data acquisition plan. We're looking at the experience of ROSEN compact platforms.
Read article →International research
Thick wall and variable diameter: how to reconcile conflicting requirements for the inspection tool
Marine PII projects show why magnetic system reserve, storage mechanics and phased testing should be designed together.
Read article →International research
Blend, metal loss and magnetic response: Why analyse the damage together
The TDW approach to several data sets helps understand why the same dent depth may correspond to different mechanical situations.
Read article →International research
Cleaning of variable diameter pipe: How to turn each passage into a data source
The Gjøa experience shows the relationship between the design of the treatment device, paraffin sediments and preparation for subsequent inspection.
Read article →International research
Long-term sea runs: what Blue Flow Inspection teaches
The magnetic control of the long gas line requires a reconciliation of pressure, resource, cleaning, tracking and data preservation.
Read article →International research
Directional waves in the gas pipeline: How to check crack search technology
From selecting acoustic fashion to checking the size of crack: engineering issues to developing instruments on directed waves.
Read article →International research
MFL-A and MFL-C co-processing: from two signals to a metal loss model
ROSEN's work on IPC 2024 is a starting point for data integration, model training and engineering results testing.
Read article →Data and research
Intensive deformed state: how survey and calculation are related
What is the measurement of the pipeline and what are the baseline data for evaluating strength?
Read article →
Magnetic inspection
MFL and TFI: Why change the direction of magnetic field
How the orientation of magnetation relates to the form of the anomalies being detected.
Read article →
Geometry
Pipe profile and track coordinates: different measurement tasks
What the caliper tool shows and how its data differ from navigation reference.
Read article →
Inspection system design
Multi-section tools and combined inspection
Why are the number of sections and the number of measurement methods — It's not the same thing.
Read article →Data and research
Why Speedes the Magnetic Signal
Research view of the speed connection, sensor position and MFL signal shape.
Read article →
Inspection system design
Magnetic, ultrasonic and virretical methods
A brief guide to the physical principles that are found in technical publications.
Read article →AND TECHNOLOGYDesign.
Manufacturing.
One team.No. 16 / 2024 · OKB publication
From the design bureau
Engineering experience
in print
How OKB grew out of the research centre, brought engineering and production together and developed its own inspection tools.
Read the article on the research centre’s website ↗View the journal issue ↗